Effects of the tube diameter on the propagation of helium plasma plume via electric field measurement
S. Wu,Xinpei Lu,Yuanfu Yue,Xi Dong,X. Pei
DOI: https://doi.org/10.1063/1.4964280
IF: 2.2
2016-01-01
Physics of Plasmas
Abstract:In this work, the dependence of the length of plasma plume, propagation velocity, electric field in the streamer head, and propagation mode transition on the tube diameter varied in the range of 0.07-4 mm is investigated for the first time. The atmospheric-pressure helium plasma plume, ignited by a positive pulsed direct current voltage with a pulse rising time of 60 ns, is confined inside a long glass tube. First, the decreased tube diameter results in the reduction of the length of plasma plume but the growth of aspect ratio of plasma plume. Second, as the tube diameter decreases, the average velocity of the propagation of plasma plume increases first, then reaches a maximum value at tube diameter of 1 mm, and finally decreases for the tube diameter decreasing further. Third, the electric field in the streamer head, determined by the method based on Stark polarization spectroscopy of He 447 nm line, increases monotonically from 9 kV/cm to 20 kV/cm with the tube diameter decreasing from 4 mm to 0.6 mm. Finally, when the tube diameter is further reduced to 0.07 mm, high-speed photography reveals that the propagation mode of the plasma plume transits from the plasma bullet to the continuous plasma column. Published by AIP Publishing.
What problem does this paper attempt to address?