Fiberoptic bronchoscopic dilation for central airway stenosis

张红,王广发,阙呈立,李海潮,迟春花,李楠,章巍,魏淑敏
DOI: https://doi.org/10.3969/j.issn.1008-1070.2004.08.009
2004-01-01
Abstract:Objective To evaluate the efficacy and safety of fiberoptic bronchoscopic balloon dilation in the treatment of benign central airway stenosis. Methods Five patients with constrictive tracheo-bronchial stenosis underwent balloon dilation through fiberoptic bronchoscopy under intravenous sedation and topical anesthesia. Nine constrictive sites were dilated. Balloon catheter, threaded over the guidewire, was passed through the working cannel of bronchoscope to the target site. Dilatation processes were under the guidance of bronchoscopy. The balloon would be inflated for 30 seconds to 2minutes for each inflation and the constrictive sites were dilated several times with 2~3minutes intervals in a procedure. The dilation would be repeated every week if the airway narrowing remained. The highest pressure was limited to 12 atm for MaxForce dilator and 8 atm for CRE dilator. Results The stenosis was alleviated immediately after each dilatation for most procedures. 8 of 9 sites of airway stenosis acquired permanent improvement. The symptoms, signs, roentgenography and sprirometry showed improvement with different degree in 4 patients. The failed one was proved to have a relapse of leiomyoma. Conclusion Fiberoptic bronchoscopy guided balloon dilation is safe and effective for constrictive stenosis of central airways. Long-term outcome should be investigated in the future.
What problem does this paper attempt to address?