Ultrastructure Observation on Periimplant Osteolysis Induced by Micron - Sized Wear Particles

王友,戴尅戎
DOI: https://doi.org/10.3760/cma.j.issn.0253-2352.1999.10.114
1999-01-01
Abstract:Objective:To compare the effects of various kinds of micron - sized wear particles on osteointegration at implant - bone interface and process of periimplant osteolysis, to delineate the mechanism of aseptic loosening of artificial joint.Methods:Three special particles of ultra high molecular weight polyethylene (UHMWPE), Ti-6Al-4V and Co-Cr-Mo were used respectively to induce the change of periimplant bone structure of a well fixed implant made of titanium alloy in rabbit femur or tibia. The bone structure at implant - bone interface was observed by scanning electron microscope (SEM).Results:Ti-6Al-4V particle induced less periimplant bone surface resorption or osteolysis than that by UHMWPE or Co-Cr-Mo particles.Conclusion:Various kinds of wear particles with the same size and same amount show different capability in inducing periimplant osteolysis. Osteointegration seems to be more vulnerable to UHMWPE or Co-Cr-Mo particles.