Analysis of auxins by solidification of floating organic drop combined with high-performance liquid chromatography

LU Qiaomei,ZHANG Wenmin,HUANG Chuanhui,LU Minghua,LI Jianrong,ZHANG Lan
DOI: https://doi.org/10.7631/issn.1000-2243.2015.04.0554
2015-01-01
Abstract:Determination of two anxins ( indole propionic acid and indole butyric acid) by solidifica-tion of floated organic drop microextraction with high -performance liquid chromatography-fluores-cence detection ( SFODME-HPLC-FLD) was established.The experimental conditions affecting the extraction process were optimized.The optimal conditions of SFODME were as follows:50μL dode-canol as extraction solvent, 20.0 mL sample solution with pH 3.0 and 0.25 g · mL-1 NaCl.The above solution was extracted for 10 min at temperature of 26 ℃ and centrifugation speed of 1 800 r· min-1 .Results showed that this SFODME approach had high sensitivity and good reproducibility, with relative standard deviations lower than 8.66%.Its linear range was 0.02~60 ng· mL-1 , with the limit of detection of 0.01 ng · mL-1 and the recoveries larger than 84.3%.This method was rapid, stable and environmentally benign, and it can be applied to real sample analysis.
What problem does this paper attempt to address?