Changes in Serum Cardiac Troponin Ilevels after Percutaneous Transluminal Coronary Angioplasty
Zj Yang,Yp Jia,Jn Zhang,Kj Cao,Fm Zhang,Gs Ma,Wz Ma
DOI: https://doi.org/10.3969/j.issn.1004-8812.2000.03.004
2001-01-01
Abstract:Objective:To evaluate the possible effect on myocar di um in percutaneous transluminal coronary angioplasty (PTCA), to investigate the factors of myocardium injury after the procedure and its effect on late heart ev ents. Methods:Serum cTnI and CK-MB were measured in 173 patients wi th coronary artery disease (CAD) before PTCA and at 6 th, 12 th ,24 th, 48 th, 72th hour after the procedure respectively, and the late heart events in these p atients were followed-up. Results:The serum cTnI levels was increased after PTCA in 42 cases, kept within normal range in 84 cases, and over baseline levels before and after the procedure in 47 cases, while CK-MB was over baseli ne levels before and after the procedure only in one cases, and increased after the procedure in 10 cases. Compared with normal cTnI group, elevated cTnI was re lated to total inflation time, total pressure, dilated times as well as number o f stent implantation, contrast medium dose and occurrence of angina during infla tion(P0.05). In a follow-up of 7-36 months in 162 patients, there were 3 4 late heart events in 26 cases, and cTnI did not predict identify the late hear t events (P0.05). Conclusion:cTnI is more sensitive and specific than CK-MB in identifying minor myocardial injury during PTCA. This injury may be related to intensity of PTCA, and not enough to make worse affection.