Abstract:Fuling City which is a typical mountainous city in three gorges reservoir region was selected as the research object to investigate the temporal and spatial variation characteristics of typical pollutants in combined sewer system during the initial stage of rainfall in each functional area. The results showed that when the rainfall intensity was more than 5 mm / h,the concentration of pollutants at sampling points in sewage inspection wells of each functional area increased and then decreased with time. The different kinds of pollutants had the same peak appearance time with one peak. When the rainfall intensity was only 1. 6 mm / h,the pollutants had different peak appearance times with multiple peaks. When the rainfall intensity was 11. 7 mm / h,5. 6 mm / h and 1. 6 mm / h,the relevant peak appearance time of pollutants was more than 10 min,15 min and 20 min,respectively. In the old town with heavy traffic and high population density,the peak concentration of initial combined sewage was high,and TSS was more than 1 500 mg / L. Even if the rainfall was less than 2 mm,TSS was still more than 300 mg / L due to the large slope of pipe network in the mountainous city. There was good linear fitting between major pollutants and TSS in the initial combined sewage. So,TSS should be considered as a major pollutant that needed to be removed in the enhanced treatment of the initial combined sewage.