COMPARATIVE STUDY OF TWO-STAGE SEQUENCING REACTOR (SBR) AND CONVENTIONAL SBR

陈韬,彭永臻,田文军,彭峰,杨庆
DOI: https://doi.org/10.3969/j.issn.1000-3770.2002.06.007
2002-01-01
Abstract:Batch experiments were performed using two-stage Sequencing Batch Reactor(SBR), which consists of two SBR_s, and conventional SBR for treatment of hotel wastewater. The results showed that the COD_ Cr removal rates of both processes were equally matched. The disposal of domestic wastewater could achieve ideal effect through long-term domestication. The fluctuation of outlet using two-stage SBR was less than that using conventional SBR. The first stage was beneficial to the stabilization of outlet. The two-stage SBR process had shorter reaction time and lower energy consumption. It was indicated from the experimental results using two-stage SBR that both the two stages had not absolutely uniform mass of microbe, which was good to treat various organism in wastewater, this improved the efficiency and performance of the process.
What problem does this paper attempt to address?