Abstract:AIM:To determine the concentration of lisinopril in human plasma with HPLC-MS method for pharmacokinetics study and bioequivalence evaluation.METHODS:A Thermo Hypersil-HyPURITY C_(18) column was used with enalaprilat as internal standard and 0.1% formic aeid-methanol-acetonitrile (58∶25∶17) as the mobile phase.The analytes were ionized in the electro spray ionization (ESI) ion source of the mass spectrometer and detected in the selected ion monitoring (SIM) made.RESULTS:The calibration curve of lisinopril was linear over the range of 2.5~320μg·L~(-1).The pharmacokinetic parameters,AUC_(0-48),AUC_(0-∞),t_(max) and c_(max) of 18 subjects after taking a single dose of the trial preparation (20mg) or the reference preparation (20mg) were (1062±s 212) and (1055±214)μg·h·L~(-1),(1115±221) and (1136±224)μg·h·L~(-1), (6.1±0.6) and (6.1±0.5)h,(109±25) and (115±27)μg·L~(-1),respectively.The relative bioavailabilily was (101±13)%.There were no significant difference of main pharmacokinetic parameters between the trial preparation and the reference preparation.CONCLUSION:The method is accurate and sensitive with no endogenous interference.The two formulations ate bioequivalent.