Effect of annular seal on stability of a centrifugal pump rotor system

Wen-jie ZHOU,Le-qin WANG,Gui-kun XING,Lu-lu ZHAI,Xue-song WEI,Da-zhuan WU
DOI: https://doi.org/10.13465/j.cnki.jvs.2014.15.015
2014-01-01
Abstract:The excitation force generated by fluid in an annular seal is an important factor for instability of a centrifugal pump rotor-seal system.Here,a centrifugal pump rotor-seal system’s dynamic model was established with Muszynska nonlinear seal model,and the second-order differential equations were coverted into the first order differential equations by using the fourth-order Runge-Kutta method.The shooting method was combined with Floquet theory to study the stability and bifurcation of a centrifugal pump rotor-seal system under different seal conditions.The results showed that the system is stable with lower rotor speed;Hopf bifurcation and quasi-periodic motion emerged with increase in rotor speed;the system stability is closely related to sealing parameters,it is improved with increase in seal pressure difference, and decrease in seal gap and seal length.The results provided a theoretical basis for design of centrifugal pump rotor-seal systems and qualitative control of system stability.
What problem does this paper attempt to address?