The orthogonal preference of admixture technology about Xuesaitong for injection and its stability in different kinds of infusion

耿魁魁,汝婷婷,唐祺,刘圣
DOI: https://doi.org/10.13286/j.cnki.chinhosppharmacyj.2014.08.19
2014-01-01
Abstract:OBJECTIVE To design the best deployment process of Xuesaitong for injection,and investigate their stability in different solvents.METHODS The orthogonal experiment was designed to complete a best deployment process of Xuesaitong for injection,HPLC was used for the determination of ginsenoside Rb1which were the main ingredient in Xuesaitong in different solvents,the particle and pH of the finished product was measured after infusion,to study the stability of Xuesaitong in different solvents.RESULTS The best deployment process was as follows:using 8 ml 0.9% sodium chloride injection as a dissolving solvent injected into an ampoule,and shocked for five minutes;when the shock strength was strong,the results showed that the dissolving effect was best.Xuesaitong was dissolved within2h and the determination of ginsenoside Rb1was stable at 5%/10%glucose injection within 8 hours,the changes of pH and particle consistent were in line with pharmacopoeia,but the determination of ginsenoside Rb1declined greater than 10%at 0.9%sodium chloride injection within 8 hours.CONCLUSION It is recommended for clinical use,in accordance with the optimal deployment of the dissolution process,selecting5%/10%GS as a dilution solvent,and using it after the deployment of 8 h.
What problem does this paper attempt to address?