Experimental Study on Expanding the Space of Microwave Coagulation in Liver

陈建,徐有坤,朱东升,吉毅峥,胡晓云,施丁一,简文豪,刘英棣
DOI: https://doi.org/10.3760/j.issn:1004-4477.2003.03.011
2003-01-01
Abstract:Objective To explore ways for expanding the now-limited coagulation volume of percutaneous microwave coagulation therapy(PMCT) in liver in order to enhance the complete necrosis rate of large hepatic tumors with obviously fewer punctures. Methods Fresh pig livers in vitro and rabbit, pig livers in vivo with and without blood supply were coagulated using the self-designed HM-WIA microwave coagulator to make clear antenna length, microwave power, coagulation time and blood flow influence the microwave volume(MCV).Results The device enlarged the MCV by 3 times using single electrode with an antenna of 36 mm in length along with microwave power of 45-55 W and coagulation time of 15-19 min,the short axis of the coagulation area was 5.6 cm in vitro, 5.3 cm in vivo with no blood supply.The antenna 36 mm in length was proved the best in keeping the finest coagulation shape.The MCV was 2.8 times as large without blood supply as with it (P 0.05 ).Conclusions Innovated antenna, moderate power along with long coagulation time, ischemia tissue are key aspects leading to obviously larger MCV, which,as a result, directly reduces puncture times, meets the badly-needed effective therapy for relatively larger cancer. The strategy of making tissue ischemia before PMCT should be adopted in considering the significant influence of blood flow when large tumors are treated.