2014-01-01
Abstract:Anaerobic digestion of the self-prepared kitchen waste was carried out under the conditions of pH of 6,35 ℃ and TS of 100 g /L,and the hydrolysate produced from the kitchen waste was used as external carbon source for wastewater denitrification.The denitrification effects with methanol,sodium acetate and kitchen waste hydrolysate as carbon sources were investigated under the same COD /NO-3-N ratio.The denitrification rates of methanol,sodium acetate and kitchen waste hydrolysate were7.4,13.8 and 16.3 mgNO-3-N /(gVSS·h) respectively under the conditions of the COD /NO-3-N ratio of about 5,the initial nitrate concentration of about 35 mg /L and the normal temperature.In the denitrification process with kitchen waste hydrolysate as carbon source,the removal of nitrate went through 2 stages with different removal rates.Nitrite accumulation appeared during the denitrification process.Monod model was applied in the denitrification process,and in comparison with zero-grade reaction,the denitrification rates with Monod model for methanol,sodium acetate and kitchen waste hydrolysate as carbon source were 8.50,14.14 and 18.67 mgNO-3-N /(gVSS·h) respectively.Monod model applied in methanol and sodium acetate showed good fit of the linear relation.However,the simulation effect was not so good for kitchen waste hydrolysate due to the simultaneous reaction of different substances existing in it.