Long-term Results of Modified Maze Procedure for Patients with Atrial Fibrillation

何忠良,朱家光,陈如坤,赵百亲
DOI: https://doi.org/10.3760/cma.j.issn.1001-4497.1999.06.004
1999-01-01
Abstract:Aim:To evaluate the long term result of modified maze procedure for rheumatic heart disease (RHD) with atrial fibrillation.Clinical material and method:From March 1994 to July 1996,a modified maze procedure combined with valve replacement(mitral valve replacement in 14,double valve replacement in 4) was performed in 18 patients with RHD and atrial fibrillation.Cox maze procedure was modified with cryoablation.Results:There was no operative death.18 patients (100%)were followed up 25 to 52 months (mean,36.1 months).One patient died during follow up.Among the 17 long term survivors,8 were in NYHA functional class I,9 in class II.All maintain sinus rhythm,without recurrence of atrial fibrillation.Atrioventricular activation sequence was normal,and the atrial function was good during follow up.Conclusion:Modified maze procedure has a excellent long term result for treating atrial fibrillation and therefore should be considered for patients with RHD associated with atrial fibrillation undergoing valve replacement.