Determination of trace chromium(Ⅵ) by catalytic kinetic spectrophotometry with alizarin red-cetyltrimethyl ammonium bromide system

SHEN Shu-jun,ZOU Xiao-yong
DOI: https://doi.org/10.13228/j.issn.1000-7571.2013.12.009
2013-01-01
Abstract:In pH 5.0 HAc-NaAc buffer solution medium,with cetyl trimethyl ammonium bromide(CTMAB)as sensitizer and phenanthroline(phen)as activator,Cr(Ⅵ)had a significant catalytic effect on the oxidizing discoloration reaction between alizarin red(ARS)and hydrogen peroxide,so a novel method for the determination of trace Cr(Ⅵ) was established by kinetic spectrophotometry and the influence factors on the catalytic discoloration reaction were examined.Under the selected experimental conditions,the non-catalytic reaction system and the catalytic system had the same maximum absorption wavelength at 553nm,and Cr?in the concentration range of 0.001-0.10μg/mL showed a good linear relationship.The regression equation wasΔA = 9.404ρ(μg/mL)-0.020 7with correlation coefficient r=0.998 1and detection limit of 0.80ng/mL.The method was applied to the determination of chromium in water and soil samples.The results were consistent with those obtained by atomic absorption spectrometry,and the relative standard deviation(RSD,n=6)was 1.7%-3.0%.
What problem does this paper attempt to address?