Measurement of Posterior Slope of the Medial Tibial Plateau in Chinese

王业华,吕厚山,寇伯龙,刘帆
DOI: https://doi.org/10.3969/j.issn.1005-8478.2003.10.016
2003-01-01
Abstract:Objective: To measure the posterior slope angle of the medial tibial plateau for providing parameter of the total knee arthroplasty and the knee prosthesis design that suits for Chinese. Methods: The angles were measured between the tangent of medial tibial plateau and the perpendicular in lateral X-rays of 160 osteoarthritic knees, 80 rheumatoid knees and 120 meniscus injury knees: anterior tibial cortex (Method one); tibial proximal anatomical axis(Method two); posterior tibial cortex (Method three). Results: The posterior slope angle were 11.74°±3.87°(range -1.5°~22.5°)with the method one; 8.91°±3.57°(range -2.5°~19.5°)with the method two; 6.21°±3.51°(range -6°~17°)with the method three. The values obtained with 3 methods were different but strongly correlated ( r0.85; P0.01 ), and were not different in diagnoses and in gender. The values weakly correlated with age and were smaller than that of foreign reported with the same methods. Conclusion: The posterior slope angle of the medial tibial plateau in Chinese is smaller. These results suggest that the posterior slope angle varies among individuals and the cutting angle should be determined in each case.