Bragg Grating Strain Measurements During the Construction of A Prestressed Concrete Girder Bridge

W Moerman,W De Waele,C Coppens,L Taerwe,J Degrieck,R Baets,M Callens
2001-01-01
Abstract:This paper deals with the application of Bragg grating sensors to a prestressed concrete girder bridge with a total length of 147 m. The sensors were applied in order to measure the deformations of the bridge during the tensioning of the prestressing cables, during the push aside phase and during service afterwards. After describing the implementation of the Bragg gratings into the bridge, the measurements taken with the Bragg sensors are discussed. A comparison of these measurements with Demec measurements is performed, and strains derived on a theoretical basis, are compared wit the measurements. A good agreement was obtained. Measurements taken while the girder was pushed aside showed that this operation did not cause significant changes of the strains in the girder.