Diagnosis and Quantitative Analysis for Renal Artery Stenosis by Color Doppler Flow Imaging

尹彦玲,常毅湘,刘梅玲,刘悦,方宇,朱莉
DOI: https://doi.org/10.3760/j.issn:1004-4477.2003.08.012
2003-01-01
Abstract:Objective To explore color Doppler flow ima ging(CDFI) value in the diagnosis and quantitive analysis of renal artery stenosis(RAS) in patients of hypertension of renal vessel.Methods Fifty healthy subjects(69 branches of renal artery) and 31 cases of RAS(35 branches of renal artery) were enrolled.Respective measurement was made on the velocity of peak of renal artery(Vp), renal artery and renal artery to proximal abdominal aorta peak velocity ratio(RAR), acceleration time of section in renal artery(AT). Measurement also included ill degree of RAS,and it was comparatively analysed with Vp, RAR, AT in the ill group at the same time. Results Screening check was made on 398 cases of hypertension patient and 31 branches of renal artery showed Vp≥180 cm/s,RAR≥ 2.5-,AT≥ 0.08- s as a standard of quantitative diagnosis of RAS(stenosis degree 50%~85%).Four branches of renal artery showed Vp≤ 0.6- cm/s, RAR≤ 0.6- (stenosis degree 86%-99%), and when the renal artery completely closed,no color blood flow signal appeared in the artery.Digital subtraction angiography was made on 10 of the patients,which all showed RAS,all stenosis degree 50%,with a positive coincidence rate up to 100%.Conclusions CDFI can not only be used to diagnose RAS accurately,but also to estimate the stenosis degree.Range of Vp and RAR may correspond to pathological proportion of the stenosis.When combined with a kidney size,the above two values can be indexes for RAS degree.