Determination and Dissolution of Loxoprofen Sodium Tablets

唐翠,印春华
DOI: https://doi.org/10.3969/j.issn.1001-8255.2003.03.017
2003-01-01
Abstract:A RP HPLC method for the determination and dissolution of loxoprofen sodium tablets was presented. A Shim Pack ODS column was used, with the mobile phase of methanol water acetic acid triethylamine (600∶400∶1∶1), at the detection wavelength of 222 nm. The calibration curve was linear in the range of 5~100 μg/ml ( r =0.9999). The average recovery was 99.9% with RSD of 1.1%.
What problem does this paper attempt to address?