Self-made Side Hole Balloon for Treating No-Reflow Following Percutaneous Coronary Intervention

谭洪文,张志钢,白元,李长永,许旭东,张必利,朱嘉琦,赵仙先,吴弘
DOI: https://doi.org/10.3724/sp.j.1008.2014.00317
2014-01-01
Abstract:Objective To assess the safety and effectiveness of self-made side hole balloon for treating no-reflow following percutaneous coronary intervention(PCI).Methods Twenty-three patients diagnosed with no-reflow during PCI from Jan.2012to Jan.2013 were enrolled.Residual stenosis,thrombosis,dissection,and spasm of coronary artery were excluded.The mean age of the 23patients was(62.0±13.8)years old.Of the 23patients 14had ST segment elevation myocardial infarction(STEMI),and 9underwent elective PCI.There were 11cases with no-reflow in the left anterior descending branch,8in the right coronary artery and 4in the circumflex branch.The drugs(nitroglycerin and tirofiban)were selectively injected into the vessel using self-made side hole balloons.The thrombolysis in myocardial infarction(TIMI)grade before and after procedure,ST segment resolution(STR),ST-T changes for 24and 72hours and complications(perforation, dissection,and thrombosis of coronary artery)were observed postoperatively.Patients were followed up by ECG and echocardiogram at 1month after PCI.Incidence of major adverse cardiovascular events(MACEs)and cardiac function wereobserved 6months after PCI.Results After intracoronary administration of drug therapy,TIMI grade-1flow was found in 3 patients,TIMI grade-2flow in 5patients and TIMI grade-3flow in 15patients.In patients with STEMI,complete resolution(≥70%)was found in 8patients,partial resolution(30%-69%)in 4,and no resolution(30%)in 2.One of the 2patients with ventricular electrical storm was treated with temporary cardiac pacing and drug therapy and recovered within 1week;the other one with pericardial tamponade who was treated with emergency surgery repair died.In 9patients undergoing selected PCI,transient ST segment changes were noted in 3patients which recovered within 1week after conservative treatment;with no perforation,dissection,or thrombosis of coronary artery.One month after discharge,echocardiogram of the 22patients showed a mean left ventricular ejection fraction(LVEF)of(50.6±14.3)%and a fractional shortening in the short axis view of 0.36±0.04,and ECG showed non-specific changes of ST-T in 6patients.In 4patients with STEMI,culprit artery showed TIMI grade-3by angiography performed during PCI for non-culprit vessel 1 month after primary PCI.At 6 months after primary PCI,there was no MACE;18patients were in New York Heart Association ClassⅠand 4in ClassⅡ.ConclusionSelf-made side hole balloon is a safe,economical,effective and convenient method for intracoronary administration of nitroglycerin and tirofiban in treating no-flow during PCI,but the result still needs further verification.
What problem does this paper attempt to address?