Study and Application of Control Strategy for Primary Frequency Regulation of Once-Through Boiler

沙友平,吕剑虹,张斌,高爱民,何育生,管春雨
DOI: https://doi.org/10.3969/j.issn.1004-9649.2003.01.015
2003-01-01
Abstract:Since once-through boiler has only a small heat storage capacity,its primary frequency regulation capability is limited.On the basis of testing and analyzing the dynamic characteristics of No.1and No.2boiler units in detail in Huaneng Nanjing Power Plant ,through simulation comparison,an appropriate control strategy for the primary frequency regulation of once-through boiler unit was proposed in this paper.The practical running results showed that this improved primary frequency regulation control system could effectively keep the energy balance between once-through boiler and steam turbine.Hence in the process of promptly increasing or decreasing the unit's load under the action of primary frequency regulation control system,the throttle pressure before the steam turbine could be maintained in the safe range,thus ensuring the long-time stable operation of primary frequency regulation control system.