Comprehensive Compensation Method for the Outputs of Three-Axis Magnetometer

Xuejun ZHU,Mengchun PAN,Qi ZHANG,Chengbiao WAN,Shitu LUO,Hongfeng PANG
DOI: https://doi.org/10.3969/j.issn.1671-7449.2014.06.014
2014-01-01
Abstract:Three-axis magnetometer are widely used in detection of UXO( Unexploded Ordnance),getting the accurate geomagnetic of the measuring field is the precondition of UXO detection. But the bias error,scalar factor error and non-orthogonal error of the three-axis magnetometer and the interferential magnetic field of the vehicle both would distort the output of the three-axis magnetometerand influence the detection of UXO,so comprehensive calibration compensation should be conducted on the output error of the three-axis magnetometer. A comprehensive compensation model is established based on calibration model of magnetometer and compensation model of vehicle. Damped least-squares method is proposed to evaluate the parameters for the discomfort of iteration method solving nonlinear least squares problem. A simulation was conducted to test the effect of the method.The results of the experiment show that the method can improve the morbid of the iterative matrix,after comprehensive compensation the RMS of scalar output of the three-axis magnetometer reduced from 174. 9 n T to1. 2 n T,meets the needs of detection of UXO.
What problem does this paper attempt to address?