Low Oil Consumption-based Ignition in Combination with a Rich/lean Combustion Burner As Applied on a 600 MW Boiler

姜家仁,秦明,吴少华,秦裕琨
DOI: https://doi.org/10.3969/j.issn.1001-2060.2004.04.023
2004-01-01
Abstract:In an effort to reduce oil consumption during the startup of a pulverized coal-fired boiler a louver structured horizontal rich/lean combustion-based pulverized-coal burner in combination with a low oil consumption for ignition has been used on a 600 MW boiler. The design and tests in connection with the above scheme are described. As opposed to their traditional location in a lower primary-air port, the small oil guns for ignition are mounted in a secondary-air port in close proximity to the lower primary-air port. By taking advantage of the special features of horizontal rich/lean combustion, the small oil gun flame is made by all means possible to plunge toward the rich-combustion side of pulverized coal-air stream to achieve a complete mixing. Tests indicate the above technique is conducive to a reliable ignition of pulverized coal and stable combustion, attaining a significant oil-savings effect. Moreover, as each small oil gun has been provided with a special flame detector and incorporated into a furnace safeguard supervisory system (FSSS), a safe and reliable operation of the boiler is fully guaranteed.
What problem does this paper attempt to address?