Using a Novel Hydrogen-Terminated Porous Si Wafer to Enhance Microcystis Aeruginosa Effective Removal by Chitosan at a Low Dosage

Haiyan Pei,Hangzhou Xu,Hongdi Xiao,Jiongming Sun,Wenrong Hu,Xiuqing Li,Chunxia Ma,Yan Jin
DOI: https://doi.org/10.1016/j.colsurfa.2016.04.015
IF: 5.518
2016-01-01
Colloids and Surfaces A Physicochemical and Engineering Aspects
Abstract:A novel hydrogen-terminated porous Si wafer (H-PSi wafer), which could produce active radicals under visible light irradiation and has a good reusability, was proposed to enhance the Microcystis aeruginosa removal intactly by chitosan coagulation at a low dosage. The surface charge of M. aeruginosa, cell integrity, and release of intracellular organic matter from M. aeruginosa were investigated after H-PSi wafer pre-oxidation to reveal the related mechanism. The results show that, the surface charge of M. aeruginosa could be decreased after pre-oxidation, which is helpful to coagulation by the charge neutralization. Moderate pre-oxidation with suitable area of H-PSi wafer could avoid the intracellular organic matter released from algal cells and decrease the level of dissolved organic matter, and then the removal rate of M. aeruginosa by coagulation could be increased obviously. However, excessive pre-oxidation with larger area of H-PSi wafer will damage the algal cells, with intracellular organic matter releasing and the coagulation efficiency reducing. Furthermore, appropriate pre-oxidation could also effectively decrease the concentration of extracellular microcystins after chitosan coagulation. This study provides a promising technique to remove the toxic algae effectively and prevent the harm of blooms to drinking water production. (C) 2016 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?