Numerical Study of Solenoid Value Head Temperature Field of Control Rod

Yin Yuan,Liu Qianfeng,Bo Hanliang,Wang Lu
DOI: https://doi.org/10.3724/sp.j.1249.2014.02119
2014-01-01
Abstract:A hydraulic drive control rod is a new control technology of nuclear reactor. The direct action solenoid valve is a key component of this technology. The performance of the direct action solenoid valve directly affects the stable operation of control rod hydraulic drive system. The temperature field of the head of the direct action solenoid valve with various currents was studied using the ANSYS software. The result shows that the temperature of the head of the solenoid valve increases as the current increasing. The temperature of the middle head is higher than that of the edge of the head and the highest temperature of the middle head is under the limiting temperature. The tempera-ture of the inner wall of the head is higher than that of the exterior wall. The results calculated by ANSYS were veri-fied with the experimental testing.
What problem does this paper attempt to address?