Determination of Anions in Lithium-Ion Batteries Electrolyte by Ion Chromatography

Bin-He Zhu,Cheng-Zhu Ni,Na-Ni Wang,Xun-Yan Zhao,Wei-Qiang Guo,Pei-Min Zhang,Jia-Jie Zhang,Su-Qing Chen,Wei-De Lv,Yan Zhu
DOI: https://doi.org/10.1016/j.cclet.2016.01.037
2016-01-01
Abstract:A sensitive and accurate method based on ion chromatography was established for determination of five lithium salts in lithium-ion batteries electrolytes. Chromatographic analyses were carried out on an anion exchange column at flow rate of 1 mL/min. Under the optimal conditions, five target anions (BF4-, PF6-, TFSI-, BOB- and FSI-) exhibited satisfactory linearity with a correlation coefficient of 0.9996. The relative standard derivations of the target anions were less than less than 0.94% (n = 7). The limits of detections were in the range of 0.068-0.29 mg/L with average spiked recoveries ranging from 96.8% to 105.1%. (C) 2016 Chinese Chemical Society and Institute of Materia Medica, Chinese Academy of Medical Sciences. Published by Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?