Effects of total hip replacement combined with tension band wire fixation for intertrochanteric four-part fractures with hip diseases
Can CAO,Jing YANG,Fu-xing PEI,Bin SHEN,Zong-ke ZHOU,Peng-de KANG
DOI: https://doi.org/10.3969/j.issn.2095-252X.2015.12.014
2015-01-01
Abstract:Objective To explore the surgical technique and efficacy of total hip replacement combined with tension band wire fixation for intertrochanteric four-part fractures with hip diseases. Methods Twenty-eight cases of intertrochanteric four-part fractures and hip diseases treated with total hip replacement by a full coated, collared femoral prosthesis from September, 2005 to September, 2009 were included. Before fracture, there were 19 cases with osteoarthritis, 4 cases with osteoarthritis secondary to hip developmental dysplasia, 2 cases with femoral head necrosis, 3 cases with rheumatoid arthritis of hip, all acetabular sides had lesions involved. All were of four-part fractures ( type III in the Evans-Jensen classification ). Preoperatively, visual analogue scales ( VAS ) were marked. X-ray films were taken before and the first day after the surgery. Follow-up evaluations were performed at1, 2, 3, 6, and 12 months, and every year thereafter. Harris score and VAS were recorded, X-ray films and physical examination were taken in each follow-up. Results All cases were followed for 5-8 years, with an average of 6.3 years. One month after the surgery, the average Harris score was 69.4±7.3. Half a year after the surgery, the average Harris score was 90.3±5.7. At the last follow-up, the average Harris score was 92.4±5.6. Results were excellent in 21 cases, good in 5 cases, fair in 2 cases, with an excellent and good rate of 92.8%. The score half a year after the surgery was significantly higher than that 1 month after the surgery with statistical significance ( t=-47.55, P=0.00 ), and the score at the last follow-up was significantly higher than that half a year after the surgery with statistical significance ( t=-8.87, P=0.00 ). Before the surgery, the average visual analogue scale was 6.0±1.0; 1 month after the surgery, the average scale was 2.0±0.7; at the last follow-up, the average scale was 0.5±0.6. The scale 1 month after the surgery was significantly lower than that before the surgery with statistical significance ( t=28.69, P=0.00 ), and the scale at the last follow-up was significantly higher than that 1 month after the surgery with statistical significance ( t=8.80, P=0.00 ). One patient had hip dislocation by falling 2 weeks after surgery, but no more dislocations happened after the closed reduction. All X-ray films showed the satisfied press-fitting the day after surgery, and the prostheses were well fixed. At 4-months follow-up, all fractures healed with no wires broken. Until the last evaluation, there were not any complications of loosening, subsidence or periprosthetic fracture, deep infection. All trendelenburg signs were negative and no obvious limp. Conclusions Total hip replacement by a full coated, collared femoral prosthesis combined with tension band wire fixation of the greater and less trochanters fragments for intertrochanteric four-part fractures with hip diseases can gain satisfied outcomes.