Quantitative Study on Exact Reconstruction Sampling Condition in Limited-view CT

Bin Yan,Wenkun Zhang,Lei Li,Hanming Zhang,Linyuan Wang
DOI: https://doi.org/10.48550/arxiv.1601.06221
2016-01-01
Abstract:In limited-view computed tomography reconstruction, iterative image reconstruction with sparsity-exploiting methods, such as total variation (TV) minimization, inspired by compressive sensing, potentially claims large reductions in sampling requirements. However, a quantitative notion of this claim is non-trivial because of the ill-defined reduction in sampling achieved by the sparsity-exploiting method. In this paper, exact reconstruction sampling condition for limited-view problem is studied by verifying the uniqueness of solution in TV minimization model. Uniqueness is tested by solving a convex optimization problem derived from the sufficient and necessary condition of solution uniqueness. Through this method, the sufficient sampling number of exact reconstruction is quantified for any fixed phantom and settled geometrical parameter in the limited-view problem. This paper provides a reference to quantify the sampling condition. Using Shepp-Logan phantom as an example, the experiment results show the quantified sampling number and indicate that an object would be accurately reconstructed as the scanning range becomes narrower by increasing sampling number. The increased samplings compensate for the deficiency of the projection angle. However, a lower bound of the scanning range is presented, in which an exact reconstruction cannot be obtained once the projection angle is narrowed to this extent no matter how to increase sampling.
What problem does this paper attempt to address?