Electromagnetic and Thrust Characteristics of Double-sided Permanent Magnet Linear Synchronous Motor Adopting Staggering Primaries Structure.

Xu Zhen Huang,Jing Li,Chengming Zhang,Zhen Yu Qian,Liyi Li,David Gerada
DOI: https://doi.org/10.1109/tie.2018.2860526
IF: 7.7
2018-01-01
IEEE Transactions on Industrial Electronics
Abstract:Traditionally, straggering the primaries of the double-sided permanent magnet linear synchronous motor (DS-PMLSM) is beneficial in helping to reduce the detent force caused by the longitudinal end effect, but leading to a reduction of the average thrust. To overcome this disadvantage, this paper provides a novel DS-PMLSM, which adopts the structure of staggering two primaries and rearranging windings. First, the characteristics of the voltage and detent force are analyzed theoretically and verified by finite element (FEM) simulations. The inductance, thrust, and normal forces are then compared with the traditional DS-PMLSM. Furthermore, the geometrical parameters are optimized to improve the thrust. Finally, one DS-PMLSM prototype is tested. The detent force and back electromotive force tested results verify the effectiveness of the topology proposed in this research.
What problem does this paper attempt to address?