Immunology Status of Patients During Kidney Transplant.

Saniya Abdrakhmanova,Aida Turganbekova,Zhuldyz Zhanzakova,Kuralay Zhangaziyeva
DOI: https://doi.org/10.6002/ect.mesot2023.p12
2024-01-01
Experimental and Clinical Transplantation
Abstract:OBJECTIVES: The immunology status of a patient has a crucial role in kidney transplant. We investigated the effectiveness of a desensitization protocol, guided by the immunology status of patients, for kidney transplant candidates.MATERIALS AND METHODS: Antibody screening for human leukocyte antigens was conducted with the Luminex single-antigen microsphere bead assay method for 34 patients from June 2021 to June 2022. Donor human leukocyte antigen genotypes at 8 loci (A*, B*, С*, DRB1*, DQA1*, DQB1*, DPA1*, and DPB1*) were determined, to correlate the specificities of recipient human leukocyte antigen antibodies with donor antigens and identify unacceptable donor antigen combinations. Specialized immunology studies measured panel reactive antibody levels and human leukocyte antigen class I and class II antibodies. A crossmatch compatibility test using complementdependent cytotoxicity was conducted.RESULTS: Of the 34 patients, 10 completed all 3 stages of the desensitization therapy. Most patients experienced decreased sensitization to human leukocyte antigen class I and class II antibodies. Two patients achieved complete clearance of A1 and DQ5 antibodies, respectively, whereas 1 patient exhibited an increase in donor-specific antibody mean fluorescence intensity. Prior to desensitization therapy, the crossmatch compatibility test yielded positive results with T and B lymphocytes. After completing the therapy, the crossmatch test showed negative results in 4 cases with T lymphocytes and positive results with B lymphocytes. Plasmapheresis sessions effectively reduced circulating antibodies. However, the combination of rituximab and plasmapheresis alone did not achieve a negative crossmatch test required for kidney transplant.CONCLUSIONS: It is crucial to assess the reduction of donor-specific antibody quantity, considering both the percentage and the mean fluorescence intensity. To avoid false-positive results in crossmatch analysis, drug half-life must be considered. Laboratories should have various crossmatch techniques, such as flow cytometry and single-antigen microsphere bead assay technology, available for research and urgent cases that require crossmatch analysis.
transplantation
What problem does this paper attempt to address?