In Vivo Monitoring of Oxygen in Rat Brain by Carbon Fiber Microelectrode Modified with Antifouling Nanoporous Membrane

Lin Zhou,Hanfeng Hou,Huan Wei,Lina Yao,Lei Sun,Ping Yu,Bin Su,Lanqun Mao
DOI: https://doi.org/10.1021/acs.analchem.8b05658
IF: 7.4
2019-01-01
Analytical Chemistry
Abstract:Oxygen (O-2) is involved in many life activities, and its in vivo monitoring is of vital importance. In vivo electrochemistry with carbon fiber microelectrode (CFME) has been proven to be a suitable technique, but the surface fouling propensity poses a great challenge to its current stability and reliability. Herein we electro-grafted silica nanoporous membrane (SNM) consisting of uniform, closely packed, and vertically aligned nanochannels on the CFME surface, which was capable of protecting the surface effectively from biofouling and, meanwhile, preserving the permeability to O-2. In comparison with a bare CFME, the SNM/CFME after implantation in the brain of a live rat maintained its analytical sensitivity to O-2. Moreover, the implanted electrode could monitor O-2 continuously under the in vivo condition, exhibiting an excellent current stability, as well as a fast response, up to 2 h. Further considering the high permeability, selectivity, and biocompatibility of SNM, we believe the modified CFME is a highly reliable sensor for long-term in vivo monitoring of O-2, as well as other neurochemicals, with promise in physiological, ethological, and neurological studies.
What problem does this paper attempt to address?