Abstract:The multiplex 3-phase winding motors suffer from the problem of the magnetic coupling between the normal winding and the fault winding. To investigate the behaviors of the dual-winding PMSMs on the short-circuited fault conditions, a fault analysis model is developed that includes a dual-winding PMSM circuit model with a short-circuited fault coil within some phase coil and an inverter model with a vector control. The 1/10 and 1/4 turn-to-turn short-circuited faults are simulated with a customized dual-winding PMSM of 4.7 kW. The results show that even with a short-circuited current up to three times of the rated value, the damping torque produced by the fault current can be compensated if the motor windings and their driving inverters have a back-up capacity of about 30% the rated value. An experimental platform with the 4.7kW dual-winding PMSM is built for verifying the analysis model. The simulated waveforms are very close to the measured ones not only for the turn-to-turn short-circuited but also for phase-to-phase short-circuited faults. With the short-circuited current being limited to the rated value, the damping torque produced by the phase-to-phase short-circuited current is too large to be compensated.
What problem does this paper attempt to address?