Production, Quality Control of Next-Generation PET Radioisotope Iodine-124 and Its Thyroid Imaging

Feng Wang,Teli Liu,Liqiang Li,Xiaoyi Guo,Dongban Duan,Zhibo Liu,Hua Zhu,Zhi Yang
DOI: https://doi.org/10.1007/s10967-018-6277-3
2018-01-01
Journal of Radioanalytical and Nuclear Chemistry
Abstract:In this paper, 124Te(p,n)124I nuclear reaction was used for 124I production. The 124TeO2/Al2O3 target was irradiated by 12.5 MeV proton at 20 μA for 3–8 h in a medical cyclotron. After irradiation, 124I was purified by dry distillation and dissolved in 0.02 M NaOH, with radioactivity 370–1480 MBq. Micro-PET/CT imaging of 124I in healthy mice showed the thyroid and stomach accumulations and kidney metabolism, which may be useful for thyroid disease diagnosis. In summary, we have produced next-generation PET radioisotope 124I routinely in sufficient and high quality.
What problem does this paper attempt to address?