Diagnostic value of Vascular functionnal parameters in dynamic contrast-enhanced MRI for pituitary microadenomas

zhang yumei,wang qing,he jingzhen,wang fang,wang jieqiong,xu xinghua
2017-01-01
Abstract:Objective To investigate quantitatively microvascular parameters in pituitary microadenomas by dynamic contrastenhanced magnetic resonance imaging( DCE-MRI). Methods MRI date was analyzed in 20 normal female adenohypophysis,24 patients with hyperprolactinemia and 34 patients with pituitary hyperprolactinemia microadenomas conformed with clinical,laboratory examination or diagnostic treatment retrospectively. The microvascular function parameters of pituitary gland( volume transfer constant,K;; extravavascular extracelluar volume fraction,Ve; rate constant,K;; time to peak,TTP) were obtained. A t test was used to compare the difference of parameters between microadenomas and its surrounding pituitary tissue. Analysis of variance( ANOVA) was used to evaluate the difference of parameters among these three groups and the difference of parameters of left,median and right pituitary gland in control group. Least significant difference( LSD) was used for pairwise comparison. The sensitivity and specificity of each parameter in diagnosing pituitary microadenomas were analyzed by ROC curve. A P value of ≤0. 05 was considered significant. Results 1) TTP value was significantly lower in media pituitary gland than that in left and right pituitary gland; 2) K;and K;value of pituitary microadenomas were significantly lower and TTP value of pituitary microadenomas was significantly higher than those of their surrounding tissue respectively; 3) K;and K;value were significantly lower and TTP value was significantly higher in microadenomas group than those in both hyperprolactinemia and control group. There was no significant difference in K;,K;and TTP between hyperprolactinemia and control group; 4) The diagnostic efficacy of K;and K;was significantly higher than that of TTP for micro-adenomas. The diagnostic efficacy of the combined use of K;-K;was significantly higher than that of the combined use of K;-TTP,and TTP and K;,respectively. The diagnostic efficacy of the combined use of K;-K;-TTP was the highest for microadenomas. Conclusion The vascular functionnal parameters in DCE-MRI could quantitatively analyze the microvascular change of pituitary microadenomas,parameter K;show higher diagnostic efficacy and the combined use of multi-parameters is helped to improve the diagnosis of pituitary microadenomas.
What problem does this paper attempt to address?