Abstract:For oxy-fuel combustion boilers aiming at reducing CO; emission,a steady-state model was established to measure the flow rate and component of the gas in the air/gas combustion system,and subsequently to find the interrelation between the system operating parameters and the governing way of gas variables.Results show that the gas flow rate and its component calculated by the model are close to actual measurements,with both errors less than 5%.The model is therefore proved to be reasonable and effective in providing quantitative basis for the design and running of oxy-fuel combustion systems,which may also serve as a reference for relevant measurement configuration,instrument selection,quantitative governing and device manipulation of air/gas combustion systems.
What problem does this paper attempt to address?