Study on Heat-transfer Characteristics of a 200 MW Oxy-fuel Coal-fired Boiler

wang peng,liu chaohui,liao haiyan,li yanbing,zhu haiyue,li xiangyu,chen yinbiao
DOI: https://doi.org/10.3969/j.issn.1674-7607.2014.07.002
2014-01-01
Abstract:Amendments were made to the heat-transfer calculation method for conventional air combustion to make it applicable to oxy-fuel combustion mode.Moreover,parameter optimization and modification were conducted to the weighted sum of gray gases(WSGG)model,so as to obtain the variation law of gas emissivity with the flue gas temperature,effective thickness of radiation layer and with the pressure ratio.Taking the database of American National Institute of Standards and Technology(NIST)as the criteria,physical parameters such as heat conductivity,kinematic viscosity and Prandtl number of gas components under oxy-fuel combustion mode were fitted,and the method for convective heat-transfer calculation was improved by calculation steps of first single components then their mixtures,which subsequently was used to a 200 MW oxy-fuel coal-fired boiler.Results show that the error between fitted physical parameters and actual measurements of CO2 in flue gas is less than 0.61%under oxy-fuel combustion mode;main parameters such as the heat absorption of various heating surfaces and the outlet gas temperatures under oxy-fuelcombustion mode with both 26%oxygen concentration in dry recycle condition and 29%oxygen concentration in wet recycle condition agree well with those under corresponding air combustion mode,indicating that the compatibility can basically be reached between above two combustion modes for the same boiler.
What problem does this paper attempt to address?