Overlapped Stenting Combined with Coiling for Blood Blister-Like Aneurysms: Comparison of Low-Profile Visualized Intraluminal Support (lvis) Stent and Non-Lvis Stent

Deyuan Zhu,Yibin Fang,Pengfei Yang,Ping Zhang,Lei Chen,Yi Xu,Bo Hong,Qinghai Huang,Jian-Min Liu
DOI: https://doi.org/10.1016/j.wneu.2017.03.092
IF: 2.21
2017-01-01
World Neurosurgery
Abstract:OBJECTIVE: To evaluate the safety and efficacy of overlapped stenting for blood blister-like aneurysms (BBAs) and to compare the outcomes between Low-profile Visualized Intraluminal Support (LVIS) and non-LVIS stents.METHODS: A retrospective review of the aneurysm database identified 37 patients with intracranial carotid artery BBAs treated by overlapped stenting in our institution from June 2013 to June 2016. The clinical characteristics and angiographic results were reviewed.RESULTS: Overlapped stenting combined with coiling were applied in 37 BBAs, including LVIS stents in 18 cases and non-LVIS stents in 19. For the LVIS group, angiographic results at 3-24 months were complete occlusion in 15 cases (83.3%), improved in 2 cases (11.1%), and recanalized in 1 case (5.6%). The modified Rankin Scale scores at 3-36 months' follow-up were 0-2 in 15 cases (83.3%) and 3-6 in 3 cases (16.7%). For the non-LVIS group, angiographic results at 3-46 months were complete occlusion in 12 cases (63.2%) and recanalized in 7 cases (36.8%). Clinical outcomes at 6-58 months were modified Rankin Scale scores of 0-2 in 17 cases (89.5%) and 3-6 in 2 cases (10.5%). Use of the LVIS stent was less likely to result in recanalization (odds ratio 0.10, 95% confidence interval 0.01-0.93, P [0.042) than the non-LVIS stent. The LVIS group had a lower average number of stents than did the non-LVIS group (2.2 vs. 2.6, P [0.016). In terms of complication rate (11.1% vs. 5.3%, P [0.604), good outcome rate (83.3% vs. 89.5%, P [0.660), and immediate angiographic result (P [0.424), no statistically significant difference between the 2 groups was found.CONCLUSIONS: Overlapped LVIS stenting combined with coiling is feasible and safe for BBAs. Overall, the LVIS stent provided less risk of BBA recurrence compared with the non-LVIS stent and did not increase the risk of procedure-related complications.
What problem does this paper attempt to address?