Biomechanical and Histopathology Evaluation on Osseointegration Ability of Two Types Zirconia in Vivo
Han Jianmin,Lin Hong,Hong Guang,Shimizu Yoshinaka,Sasaki Keiichi
DOI: https://doi.org/10.3389/conf.fbioe.2016.01.00290
IF: 5.7
2016-01-01
Frontiers in Bioengineering and Biotechnology
Abstract:Event Abstract Back to Event Biomechanical and histopathology evaluation on osseointegration ability of two types zirconia in vivo Jianmin Han1, Hong Lin1, Guang Hong2, Yoshinaka Shimizu3 and Keiichi Sasaki4 1 Peking University School and Hospital of Stomatology, Dental Materials, China 2 Tohoku University Graduate School of Dentistry, Liaison Center for Innovative Dentistry, Japan 3 Tohoku University Graduate School of Dentistry, Department of Pathology, Japan 4 Tohoku University Graduate School of Dentistry, Division of Advanced Prosthetic Dentistry, Japan Purpose: The purpose of this study is to evaluate the biomechanical and histological behavior of ceria-stabilized zirconia/alumina nanocomposite (NANOZR) (Panasonic Health Care Co., Tokyo, Japan) in comparison to yttria-stabilized zirconia (3Y-TZP) (Panasonic Health Care Co., Tokyo, Japan) in the rat. Methods: The NANOZR, 3Y-TZP cylindrical implants (diameter: 1mm, length: 2mm) were used. The three-dimension surface morphology and surface roughness were determined by scanning white light interferometry (Wyko NT1100, Veeco Instruments Inc., Tucson, USA). The cylindrical zirconia implants were placed at the distal edge of the Wister rat (8W, Male) femur. At weeks 2, 4 and 8, the interfacial shear strength between implant and bone were measured by push-in test using universal testing machine (Model 5565, Instron Co., Canton, Mass, USA). The bone formation and osteoclast amount of peri-implant was evaluated using a microfocus X-ray CT system (SMX-225CT, Shimadzu Co., Kyoto, Japan) and hard tissue slice. Results: The average surface roughness of 3Y-TZP (Sa, 0.788 µm) is significant higher than the NANOZR (Sa, 0.559 µm). There are similar shear strength between 3Y-TZP and NANOZR at 2 weeks, but at weeks 4, 8, the shear strength of NANOZR is higher than 3Y-TZP. ( The X-ray show there is new bone formation around the both types zirconia implants after 4 weeks. The bone-implant contact is increasing during the observation periods, there is no significant difference for the bone implant contact for the two materials. The osteoclast can be observed at 2 weeks, however, there is no osteoclast can be found at 4 weeks and 8 weeks. Both of two types zirconia had successfully osseointegration. Conclusion: NANOZR has preferable bioactivity compare with 3Y-TZP. Further studies are necessary for potential biologic mechanisms involved. Keywords: in vivo, Implant, Bioactivity, bioinerface Conference: 10th World Biomaterials Congress, Montréal, Canada, 17 May - 22 May, 2016. Presentation Type: Poster Topic: Biomaterials evaluation in animal models Citation: Han J, Lin H, Hong G, Shimizu Y and Sasaki K (2016). Biomechanical and histopathology evaluation on osseointegration ability of two types zirconia in vivo. Front. Bioeng. Biotechnol. Conference Abstract: 10th World Biomaterials Congress. doi: 10.3389/conf.FBIOE.2016.01.00290 Copyright: The abstracts in this collection have not been subject to any Frontiers peer review or checks, and are not endorsed by Frontiers. They are made available through the Frontiers publishing platform as a service to conference organizers and presenters. The copyright in the individual abstracts is owned by the author of each abstract or his/her employer unless otherwise stated. Each abstract, as well as the collection of abstracts, are published under a Creative Commons CC-BY 4.0 (attribution) licence (https://creativecommons.org/licenses/by/4.0/) and may thus be reproduced, translated, adapted and be the subject of derivative works provided the authors and Frontiers are attributed. For Frontiers’ terms and conditions please see https://www.frontiersin.org/legal/terms-and-conditions. Received: 28 Mar 2016; Published Online: 30 Mar 2016. Login Required This action requires you to be registered with Frontiers and logged in. To register or login click here. Abstract Info Abstract The Authors in Frontiers Jianmin Han Hong Lin Guang Hong Yoshinaka Shimizu Keiichi Sasaki Google Jianmin Han Hong Lin Guang Hong Yoshinaka Shimizu Keiichi Sasaki Google Scholar Jianmin Han Hong Lin Guang Hong Yoshinaka Shimizu Keiichi Sasaki PubMed Jianmin Han Hong Lin Guang Hong Yoshinaka Shimizu Keiichi Sasaki Related Article in Frontiers Google Scholar PubMed Abstract Close Back to top Javascript is disabled. Please enable Javascript in your browser settings in order to see all the content on this page.