Detection and stability of Pidotimod by high performance liquid chromatography

fu luoqin,fu aikun,li lin,hu shenglan,li weifen
DOI: https://doi.org/10.3969/j.issn.1008-0589.2016.05.09
2016-01-01
Abstract:Pidotimod is an artificial synthetic immune modulators with oral immune modulator. A effective high performance liquid chromatography(HPLC) method was established for determination of pidotimod. Waters e2695 high performance liquid chromatograph was adopted with Sun Fire;C18(4.6 mm×250 mm, 5 μm) column, and the mobile phase was 0.01 mol/L sodium dihydrogen phosphate solution(p H=2.5)-methanol-isopropyl alcohol(92∶7∶1) at a flow rate of 1.0 m L/min, at 30 ℃. The detection wavelength was set at 206 nm with 10 μL sample size. The linear range of pidotimod was 0.618 to 2.575 mg/m L, and the regression equation was y=0.068x-0.0251, R2=0.9989. The average recovery was 99.02% with corresponding RSD of 0.627%.Stability tests showed that the pidotimod was relatively thermal stable under 100 ℃. The residue amount of pidotimod treated for10 min under 80 ℃ or treated for 3 min under 90 ℃ and 100 ℃ was maintained at above 91%; the stability in simulated gastric and intestinal juice was also acceptable, and the residue percentage was more than 96% when treatment time less than 150 min.These results demonstrated that pidotimod might be used in poultry and livestock without additional treatment. Moreover, this study provided a reference for pidotimod processing, preparation of different preparations, storing condition selection and application in poultry and livestock feeding industry.
What problem does this paper attempt to address?