High-Performance Separation of Fullerenes on Metal-Organic Framework Mil-101(Cr)
Cheng-Xiong Yang,Ying-Jun Chen,He-Fang Wang,Xiu-Ping Yan
DOI: https://doi.org/10.1002/chem.201101593
2011-01-01
Chemistry
Abstract:The discovery of C60 and C70 has evoked a series of investigations in chemistry, physics, and materials sciences, and has stimulated the development of new separation and purification methods for fullerenes. High-performance liquid chromatography (HPLC) is the best technique of choice, and has been widely used for the separation and purification of fullerenes on various stationary phases. Metal–organic frameworks (MOFs) are an emerging class of microporous materials, and their unusual properties such as permanent nanoscale porosity, high surface area, uniform structured cavities, and the availability of in-pore functionality and outer-surface modification are advantageous for diverse applications including gas adsorption and storage, catalysis, drug delivery, sensing, and imaging. Large diversity in structure, adsorption affinity, pore size, high surface area, and pore volume next to the minimal dead volumes make MOFs suitable advanced chromatographic separation media. Recently, several MOFs, such as MOF-5, HKUST-1, MIL-47, and MIL-53 have been successfully used as the stationary phases for HPLC separation of small molecules. Potential applications of MOFs for HPLC separation of carbon nanomaterials like fullerenes should be considerable, but has not been explored so far. Herein we report the exploration of MOFs as the stationary phase for HPLC separation of fullerenes with excellent selectivity and high throughput. To demonstrate the proofof-concept, we used MIL-101(Cr) as the stationary phase for HPLC because of its high surface area, large windows (12 and 16 14.5 ), mesoporous pores (29 to 34 ), and excellent chemical and solvents stability. MIL-101(Cr) is built up from a hybrid supertetrahedral building unit, which is formed by terephthalate ligands and trimeric chromium octahedral clusters. Even though its excellent properties, MIL-101(Cr) has never been explored as HPLC stationary phase before. MIL-101(Cr) was synthesized according to F rey et al. (See the Supporting Information). The successful preparation of MIL-101(Cr) was confirmed by X-ray diffraction (XRD), thermal gravimetric analysis (TGA), and scanning electron microscopy (SEM) (Figure S1–S3 in the Supporting Information). The suspension of MIL-101(Cr) in dichloromethane (CH2Cl2) was slurry-packed into a stainless steel column (5 cm long 4.6 mm i.d.) under 6000 psi for 10 min. The performance of the MIL-101(Cr) packed column was firstly demonstrated for the separation of C60 and C70. As shown in Figure 1, the MIL-101(Cr) packed column (5 cm