Diagnostic Capacity of Electron Cyclotron Emission Imaging System with Continuous Large Observation Area on EAST Tokamak.

BingXi Gao,JinLin Xie,ZhenLing Zhao,ChengMing Qu,Wang Liao,Xinhang Xu,WenZhe Mao,Ge Zhuang,WanDong Liu
DOI: https://doi.org/10.1063/1.5024957
2018-01-01
Abstract:Electron cyclotron emission imaging on EAST provides direct measurements of the 2-D electron temperature dynamics in a continuous large observation area with high temporal and spatial resolution. Besides the normal MHD investigation, a system with a view field large enough to cover the core plasma region has been applied to extract more plasma information, such as the plasma center location, the deposition location of auxiliary heating, and the core toroidal rotation speed. These results solely based on electron cyclotron emission imaging (ECEI) data are consistent with the results of the equilibrium fitting (EFIT), numerical code, and other diagnostics, which indicate the powerful diagnostic capacity of this ECEI system.
What problem does this paper attempt to address?