[Effectiveness of Total Hip Arthroplasty in the Treatment of Involved Hips in Patients with Ankylosing Spondylitis].

Yong Liu,Junying Sun,Tao Wang,Xijiang Zhao,Haibo Yin
DOI: https://doi.org/10.7507/1002-1892.201611018
2017-01-01
Abstract:Objective:To summarize the mid- to long-term effectiveness of total hip arthroplasty (THA) in the treatment of the involved hips in patients with ankylosing spondylitis (AS), and to investigate its influencing factors.Methods:Between March 1999 and May 2011, 32 patients (42 hips) with AS and involved hip underwent THA. There were 26 males and 6 females with a mean age of 39 years (range, 20-78 years). The disease duration ranged from 2 to 41 years, with a median of 10 years. Metal-on-polyethylene bearings were used in 19 hips, and ceramic-on-ceramic bearings in 23 hips. The diameter of prosthetic femoral head was 36 mm in 15 hips and was 28 mm in 27 hips; and all the prostheses were fixed biologically. The Harris score, visual analogue scale (VAS) score, and total range of motion (ROM) of the hip were compared between at pre- and post-operation to evaluate the effectiveness. The DeLee zone was used for describing acetabular prosthesis, the Gruen zone for describing femoral prosthesis, and the Brooker criterion for evaluating the heterotopic ossification.Results:Healing of incision by first intention was achieved in all patients after operation. There was no complication of anesthetic accident, infection, or neurovascular injury. Twenty-nine cases (39 hips) were followed up 5-17 years (mean, 9 years). Anterior dislocation of hip joint occurred in 2 hips of 24 hips (28 mm diameter), but did not in 15 hips (36 mm diameter). At last follow-up, the Harris score, VAS score, and the total hip ROM were significantly improved ( P<0.05). The shorter the disease duration was, the higher postoperative Harris score and the greater postoperative total hip ROM would be ( P<0.05); the bigger diameter of prosthetic femoral head was, the greater postoperative total hip ROM would be ( P<0.05). All the acetabular components and femoral stems were well fixed at last follow-up. The osteolysis rate around the acetabular cup in the metal-on-polyethylene bearing group (50%, 9/18) was higher than that in the ceramic-on-ceramic bearing group (0, 0/21). No prosthetic loosening was observed in 2 groups. Seven hips were found to have heterotopic ossification, including 5 hips of Brooker grade I and 2 hips of Brooker grade II.Conclusion:THA is an effective method to treat involved hips in patients with AS; especially for patients having shorter duration of the disease, THA shows better effectiveness when the bigger diameter of prosthetic femoral head and ceramic-on-ceramic bearing are used.
What problem does this paper attempt to address?