Abstract:Objective:To investigate the standardization of inflammation detecting methods in upper and lower airways.Method:After a five year cooperation with Guangzhou Institute of Respiratory Diseases on inflammatory diseases of airways,we have found a series of evaluation methodology and normative values in upper and lower airways(NO),airway hyper reactivity and cytology(Eos).Result:The normative range of nasal and pulmonary NO is 400-900 ppb and 5-25 ppb respectively.The nasal resistance increased ≥100% and FEV1 fell ≥20% when compared with their respective baselines-both illustrating a positive result.The positive value of nasal and pulmonary Eos are ≥2.00/HP and ≥2.5 % respectively.Conclusion:The standardization of evaluation methods for upper and lower airway inflammation provides the methodology and research basis for follow-up studies of upper and lower airways.