Highly Sensitive Furazolidone Monitoring in Milk by a Signal Amplified Lateral Flow Assay Based on Magnetite Nanoparticles Labeled Dual-Probe.

Lingzhi Yan,Leina Dou,Tong Bu,Qiong Huang,Rong Wang,Qingfeng Yang,Lunjie Huang,Jianlong Wang,Daohong Zhang
DOI: https://doi.org/10.1016/j.foodchem.2018.04.016
IF: 8.8
2018-01-01
Food Chemistry
Abstract:We presented a signal amplified lateral flow assay (LFA) based on magnetite nanoparticles (MNPs) labeled dual-probe and applied it in the high sensitive and rapid on-site detection of furazolidone metabolite of 3-amino-2-oxazolidinone (AOZ). The amplified signal benefited from high affinity between two probes of MNPs labeled murine monoclonal antibody (MNPs-MAb) and goat anti-mouse antibody (MNPs-GAMA) and was achieved by the generation of dual-probe network complex. This developed method could realize high sensitive detection of AOZ with a threshold value of 0.88 ng mL(-1) and a detection limit of 0.044 ng mL(-1), the sensitivity was at least 10-fold improved than that of the traditional gold nanoparticle based LFA. This facile developed assay was successfully applied for rapid detection of AOZ in milk samples. The proposed method paves a new way for on-site screening of other hazardous substances in food and can be referred in all lateral flow assays.
What problem does this paper attempt to address?