Dynamic Contrast-Enhanced MRI in Orbital Lymphoproliferative Disorders: Effects of Region of Interest Selection Methods on Time Efficiency, Measurement Reproducibility, and Diagnostic Ability.

Wen Qian,Xiao-Quan Xu,Hao Hu,Guo-Yi Su,Jiang-Fen Wu,Hai-Bin Shi,Fei-Yun Wu
DOI: https://doi.org/10.1002/jmri.25859
IF: 4.4
2017-01-01
Journal of Magnetic Resonance Imaging
Abstract:BackgroundPrevious studies indicated that dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) could serve as a useful biomarker for differentiating malignant from benign orbital lymphoproliferative disorders (OLPDs).PurposeTo investigate the influence of different region of interest (ROI) selection methods on the measurements of DCE‐MRI parameters, and their diagnostic ability in discriminating malignant from benign OLPDs.Study TypeRetrospective study.PopulationIn all, 46 patients with OLPDs (22 benign and 24 malignant).Field Strength/Sequence3.T DCE‐MRI using a 2D turbo fast low angle shot sequence postcontrast.AssessmentDCE‐MRI data were analyzed using three different ROI selection methods, including whole‐tumor ROI (ROIWT), single‐slice ROI (ROISS) and hot‐spot ROI (ROIHS). Quantitative parameters (Ktrans, Kep, Ve) were calculated based on a modified Tofts model.Statistical TestingAnalysis of variance test, intraclass correlation coefficient (ICC), Bland–Altman plots, independent t‐test, and receiver operating characteristic curve analyses were used for statistical analyses.ResultsThe time required for outlining ROIWT was significantly longer than ROISS and ROIHS (P < 0.001). The measurements of DCE‐MRI‐derived parameters based on ROIHS demonstrated lowest ICC, followed by ROISS and ROIWT. Malignant OLPDs showed significantly higher Kep than benign mimics (P < 0.001), while no significant differences were found on Ktrans (ROIWT, P = 0.535; ROISS, P = 0.557; ROIHS, P = 0.400) and Ve (ROIWT, P = 0.071; ROISS, P = 0.079; ROIHS, P = 0.057). Kep‐ROIWT showed the highest area under curve for differentiating malignant from benign OLPDs, followed by Kep‐ROISS, and Kep‐ROIHS; however, the differences were not significant (ROIWT vs. ROISS, P = 0.407; ROIWT vs. ROIHS, P = 0.363; ROISS vs. ROIHS, P = 0.887).Data ConclusionROI selection methods could have an influence on the measurements of DCE‐MRI parameters. Taking measurement time, reproducibility, and diagnostic ability into account, we suggest single‐slice ROI to be used for differentiating malignant from benign OLPDs in clinical practice.Level of Evidence: 3Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2018;47:1298–1305.
What problem does this paper attempt to address?