Determination Of Sedative And Beta-Receptor Hormone Residues In Feed By Ultra High Performance Liquid Chromatography. Tandem Mass Spectrometry

Shanshan Sun,Lijun Zhu,Yanxi Hu,Yufeng Liu,Liang Xu
DOI: https://doi.org/10.3724/SP.J.1123.2017.10025
2018-01-01
Chinese Journal of Chromatography
Abstract:An analysis and detection method for eight sedatives and fifteen beta-receptor hormones in feed was established by ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The sample was extracted with acetonitrile-1% (v/v) trichloroacetic acid aqueous solution (7:3, v/v), and purified by cationic solid phase extraction column. The extracts were separated on an Agilent Zorbax Eclipse Plus C-18 chromatographic column (100 mmx3. 0 mm, 1. 8 mu m) and then quantified via internal standard method. The results showed that the linear relationships of the 23 targets were good in the range of 2. 0-200. 0 mu g/L (r(2) > 0. 99). The average recoveries of the targets spiked in the matrix of feed samples were within 75. 1%-102. 4% in three spiked levels of 5. 0, 10, 50 mu g/kg, and the relative standard deviations (RSDs) were within 4. 3%-14. 3% (n = 6). This method with high purification efficiency and extensive scope of application can be applied to screening and detecting sedatives and beta-receptor hormones in feed.
What problem does this paper attempt to address?