Application of Transthoraic Three-Dimensional Echocardiography in the Diagnosis of Congenital Cardiac Septal Defects in Children-Compared with Two-Dimensional Echocardiography
HUANG Guo-ying,PAN Xin,LIN Qi-shan,CHEN Wei-da,CHEN Zhang-gen,Jia Bing
DOI: https://doi.org/10.3969/j.issn.1000-3630.2004.z4.009
2004-01-01
Abstract:Objective: To assess the reliability and advantage of transthoracic three-dimensional echocardiography (3DTTE) in the diagnosis of congenital cardiac septal defects. Methods: 52 patients with VSD and 20 patients with ASD were diagnosed by using 3DTTE and transthoracic two-dimensional color Doppler echocardiography (CDE), and the results were compared with surgical findings. 3DTTE was carried out by using HP/SONOS5500 with 5MHz transthoracic Omniplane rotational probe and Tomtec/4D Cardio-View RT software. Results: ①The types of VSD defined by surgery included perimembranous VSD (35) and doubly committed VSD (17), which were consistent with both CDE and 3DTTE findings. Mean diameter at major axis of VSD measured on surgery was 9.28±3.19mm, which was excellently correlated with that measured by 3DTTE ( 8.82±2.92mm) (r=0.88, p0.01) and well correlated with that measured by CDE (8.69±3.42mm) (r=0.65, p0.01). However, CDE could not define abnormal tricuspid chordae crossing the defect that happened in 4 patients with perimembranous VSDs, in whom 1 was misdiagnosed as double VSDs and 1 was misdiagnosed as diaphragm infra aortic valve. CDE only detected 2 out of 4 prolapse of aortic valve in those doubly committed VSDs. In contrast, 3DTTE displayed all the problem described above. Moreover, 3DTTE permitted detailed assessment of the positions, sizes, shapes of VSDs. ②Types of ASD defined by surgery included secundum (17), inferior veno caval (2) and superior veno caval (1), which conformed 3DTTE findings. However, CDE failed to differenciate secundum ASD from other types in this group. The diameters of ASDs at major and minor axis measured on surgery were 19.5±4.2mm and 14.8±3.7mm, which were highly correlated with those measured by 3DTTE (18.8±3.7mm and 14.0±3.3mm, respectively) (r=0.93 and 0.92,respectively, p0.01). Mean diameter of ASD measured by CDE was 18.6±4.1mm, which was also well correlated with surgical measurement(r=0.86,p0.01). Conclusion: 3DTTE provides better information on spatial recognition of the VSD and ASD and their relationship to the surrounding anatomic structures as compared with CDE, and it may become an optimal tool for clinical diagnosis in congenital cardiac septal defects.