Metal-organic Framework UiO-66 for Rapid Dispersive Solid Phase Extraction of Neonicotinoid Insecticides in Water Samples.

Xiaolin Cao,Zejun Jiang,Shanshan Wang,Sihui Hong,Hui Li,Chao Zhang,Yong Shao,Yongxin She,Fen Jin,Maojun Jin,Jing Wang
DOI: https://doi.org/10.1016/j.jchromb.2017.11.034
IF: 3.318
2017-01-01
Journal of Chromatography B
Abstract:UIO-66 crystals were explored for the first time to adsorb neonicotinoid insecticides in environmental water samples. HPLC coupled with tandem MS was used for quantification and determination of neonicotinoid insecticides. UiO-66 crystals was successfully synthesized by a simple constant-temperature bath method. Synthesized UIO-66 was characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), thermogravimetry and nitrogen adsorption porosimetry (NAP), which demonstrated a uniform particle size, a large Brunauer-Emmett-Teller (BET) surface area and high thermostability. The adsorbing results showed that UIO-66 crystals could be used as a promising adsorbents for rapid extraction of neonicotinoid insecticides and be reused at least 10 times. Under the optimized conditions, the limits of detection (LODs, S/N = 3) and limits of quantification (LOQs, S/N = 10) for the five insecticides were found to be 0.02-0.4 ng/mL and 0.05-1.0 ng/mL, respectively. This developed approach not only provided more simple and sensitive method, as well as possessing satisfactory recovery for neonicotinoid insecticides, but also for other traces in environmental samples.
What problem does this paper attempt to address?