Short-term Effects of Various Ozone Metrics on Cardiopulmonary Function in Chronic Obstructive Pulmonary Disease Patients: Results from a Panel Study in Beijing, China.

Hongyu Li,Shaowei Wu,Lu Pan,Junhui Xu,Jiao Shan,Xuan Yang,Wei Dong,Furong Deng,Yahong Chen,Masayuki Shima,Xinbiao Guo
DOI: https://doi.org/10.1016/j.envpol.2017.09.030
IF: 8.9
2017-01-01
Environmental Pollution
Abstract:Background: Short-term exposure to ambient air pollution has been associated with lower pulmonary function and higher blood pressure (BP). However, controversy remains regarding the relationship between ambient multiple daily ozone (O-3) metrics and cardiopulmonary health outcomes, especially in the developing countries. Objectives: To investigate and compare the short-term effects of various O-3 metrics on pulmonary function, fractional exhaled nitric oxide (FeNO) and BP in a panel study of COPD patients. Methods: We measured pulmonary function, FeNO and BP repeatedly in a total of 43 patients with COPD for 215 home visits. Daily hourly ambient O-3 concentrations were obtained from central-monitoring stations close to subject residences. We calculated various O-3 metrics [daily 1-h maximum (O-3-1 h max), maximum 8-h average (O-3-8 h max) and 24-h average (O-3-24 h avg)] based on the hourly data. Daily indoor O-3 concentrations were estimated based on estimated indoor/outdoor O-3 ratios. Linear mixed-effects models were used to estimate associations of various O-3 metrics with cardiopulmonary function variables. Results: An interquartile range (IQR) increase in ambient O-3-8 h max (80.5 mu g/m(3), 5-d) was associated with a 5.9% (95%Cl: -11.0%, -0.7%) reduction in forced expiratory volume in 1 s (FEV1) and a 6.2% (95% Cl: -10.9%, -1.5%) reduction in peak expiratory flow (PEF). However, there were no significant negative associations between ambient O-3-1 h max, O-3-24 h avg and FEV1, PEF. An IQR increase in ambient O-3-1 h max (85.3 mu g/m(3), 6-d) was associated with a 6.7 mmHg (95%Cl: 0.7, 12.7) increase in systolic BP. The estimated indoor O-3 were still significantly associated with reduction of FEV1 and PEF. No significant associations were found between various O-3 metrics and FeNO. Conclusions: Our results provide clues for the adverse cardiopulmonary effects associated with various O-3 metrics in COPD patients and highlight that O-3-8 h max was more closely associated with respiratory health variables. (C) 2017 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?