Development of an X-Ray Eight-Image Kirkpatrick-Baez Diagnostic System for China'S Laser Fusion Facility
Yaran Li,Baozhong Mu,Qing Xie,Yanan He,Zhiqiang Chen,Zhanshan Wang,Zhurong Cao,Jianjun Dong,Shenye Liu,Yongkun Ding
DOI: https://doi.org/10.1364/ao.56.003311
IF: 1.9
2017-01-01
Applied Optics
Abstract:This article presents the development of an x-ray eight-image Kirkpatrick-Baez diagnostic system to be used at China's Shenguang-III (SG-III) laser facility in aspects of the optical design, multilayers, and online/offline tests. Six pieces of concave spherical substrates are used for constituting a special optical structure. Dual-periodic tungsten/carbon (W/C) multilayers are used for high reflectivity and large angular bandwidth of ∼0.1°. The global spatial resolution is ∼5 μm in the ±100 μm range. The schemes of system installation, transport, collimation, and image acquisition at China's SG-III facility are also discussed.
What problem does this paper attempt to address?