Calibration of the Complex Matrix Effects on the Sampling of Polycyclic Aromatic Hydrocarbons in Milk Samples Using Solid Phase Microextraction.

Wei Lin,Songbo Wei,Ruifen Jiang,Fang Zhu,Gangfeng Ouyang
DOI: https://doi.org/10.1016/j.aca.2016.05.045
IF: 6.911
2016-01-01
Analytica Chimica Acta
Abstract:Solid phase microextraction (SPME), a simple, fast and promising sampling technique, has been widely used for complex sample analysis. However, complex matrices could modify the absorption property of coatings as well as the uptake kinetics of analytes, eventually biasing the quantification results. In the current study, we demonstrated the feasibility of a developed calibration method for the analysis of polycyclic aromatic hydrocarbons (PAHs) in complex milk samples. Effects of the complex matrices on the SPME sampling process and the sampling conditions were investigated. Results showed that short exposure time (pre-equilibrium SPME, PE-SPME) could increase the lifetime of coatings, and the complex matrices in milk samples could significantly influence the sampling kinetics of SPME. In addition, the optimized sampling time, temperature and dilution factor for PAHs were 10 min, 85 degrees C and 20, respectively. The obtained LODs and LOQs of all the PAHs were 0.1-0.8 ng/mL and 1.4-4.7 ng/mL, respectively. Furthermore, the accuracy of the proposed PE-SPME method for milk sampling was validated by the recoveries of the studied compounds in two concentration levels, which ranged from 75% to 110% for all the compounds. Finally, the proposed method was applied to the screening of PAHs in milk samples. (C) 2016 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?